This pump is designed to inject the Biofluid bacteriological treatment liquid into a convenient drainpipe usually at night after kitchen activity has ceased. The programmer allows up to 4 doses to be set, each one for a specific period of time.
The period of time for dosing, controls the amount of fluid injected - 36ml per minute. The dosing pump is factory set to turn on at 2 a.m. with a pumping period adjusted according to the size of Biomass grease trap in order to put the correct volume of Biofluid into the drainage system every night. If the pump is supplied without a grease trap then the pump must be set to inject the correct volume of Bugfluid according to the table below.
MEALS/DAY ml’s Biofluid PUMP MINUTES
|
Meals per Day |
ml's Bugfluid | Pump Minutes |
| 100 | 216 | 6 |
| 152 | 252 | 7 |
| 188 | 288 | 8 |
| 224 | 324 | 9 |
| 260 | 360 | 5 + 5 |
| 296 | 396 | 5 + 6 |
| 332 | 432 | 6 + 7 |
| 368 | 468 | 6 + 7 |
| 404 | 504 | 7 + 7 |
| 440 | 540 | 7 + 8 |
| 476 | 576 | 8 + 8 |